Water Cooled Condenser Coil
Typical tower types are induced draft forced draft cross flow induced draft and hyperbolic.
Water cooled condenser coil. It appears that your browser has javascript disabled. Placing a bare tube or a finned tube inside a steel shell makes the shelland coil condenser see fig. Water circulates through the. Condenser wshp coils.
This type of condenser is usable where refrigeration or air conditioning requirements are 1 3 ton to 3 ton. Shell and coil water cooled condenser vertical shell and coil 1 hp inlet 5 8 ids outlet 1 2 ids water 1 2 fptshell and coilcondenser water cooled. In a typical a c system the condenser coil is the one located outdoor letting out heat while the other coil the evaporator coil is located indoor chilling the. Also a water tower can be used to cool the water sent through the inside tube for cooling purposes.
I could remove the condenser and coils and place them on the other side of the wall and have some of the water from the ground loop diverted to run around the condenser. A helix tube in tube water cooled condenser is standard with refrigerant counter flow for optimum condensing unit efficiency. Where city water is used many consider this an expensive and inefficient air conditioning system. Packless water source condenser coils operate very effectively as either refrigerant condensers or refrigerant evaporators when transferring heat with water.
This website requires your browser to be javascript enabled. Simplicity of design and installation makes this product ideal in both markets. Condenser coil or heat exchanger in hvac r system cools up the substances i e. Condenser water cooled coaxial shell and coil shell and tube tube in tube mounting bracketcondenser water cooledrefrigeration equipment condenser water cooled refrigeration equipment it appears that your browser has javascript disabled.
Heat exchanger coils for condensers. Refrigerants and in turn let out latent heat from the system. The ground loop heat pump will be just 2 feet to the left of the fridge on the other side of the wall would it be possible to build a frankenstein water cooled refrigerator. Using a cooling tower to furnish the water that contacts the outside tube can further cool the condenser.
Every unit is put into a vacuum and subjected to a rigorous leak test. The condensers are usually shell and tube heat exchangers with refrigerant circulating through the shell and cooling water flowing through the tubes. Condenser water pumps circulate the hot condenser water to the cooling tower where it is cooled by air. The coils are available with packless green surface technology for improved efficiency and energy savings.
Usually the water and refrigerant flow in opposite directions. Water cooled coils do not employ fins since we are not passing air over the coil. It is typically a jacketed system with the refrigerant lines inside the water tubing. Shell and coil condenser water cooled.
This makes them an ideal choice for both water source heat pumps wshp and water cooled condenser applications.